          Position首頁 > Home > Industrial Safety Products > Safety Controller > Programmable safety controller
          SM-602 programmable safety controller

          As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

          (1) Redundancy

          (2) Difference

          (3) Self-detection


             How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


          SM-602 programmable safety controller

          1720164449995785.png

          Is a configurable safety controller, which supports the input of various safety product components.

          Maximum support for 6 sets of dual-loop inputs.

          2-way safety relay output

          4-channel semiconductor safety output, expandable output module

          Modbus protocol communicationInput and output fault indicator light

          Safety certification: PL e, Cat: 4


          Product selection

          product name

          Type number

          Safe input

          Output

          Brand

          Safety controller

          SM-602

          6CH

          2NO+4SO

          LHS

          explain

          Up to 6 sets of dual-channel safety products can be entered.

          Safety grating, emergency stop, safety door lock, reset, etc.

          Official website programming software download connection: http://lhsafety.com.cn/showinfo-257-118-0.html








          safety performance

          ? Performance level (PL): PL e

          ? Security category (Cat.): Cat.4

          ? Mission time (TM): 20 years

          ? Diagnostic coverage (DC/DC avg): 99%

          ? Safety Integrity Level (SIL): SIL3

          ? Hardware Fault Margin (HFT): 1

          ? Safe Failure Score (SFF): 99%

          ? Probability of dangerous failure (PFH d): 1.78E-9/h

          ? Stop Category: 0/1

          Complies with standard EN ISO13849

          Complies with standard EN ISO13849

          Complies with standard EN ISO13849

          Complies with standard EN ISO13849

          Conforms to standards IEC61508, IEC62061

          Conforms to standards IEC61508, IEC62061

          Conforms to standards IEC61508, IEC62061

          Conforms to standards IEC61508, IEC62061

          Complies with standard EN 60204-1


          Main technical parameters

          Power supply 

          characteristics

          ·Power supply voltage: 24VDC

          ·Voltage range: 20~30VDC

          ·Current loss: ≤110mA(24VDC)

          Input characteristics

          ·Input current: ≤10mA(24VDC)

          ·Conductor resistance: ≤15Ω

          ·Input equipment: emergency stop button, safety door, two-hand button safety light curtain, magnetic safety switch, etc.

          ·Input channel: 6

          Relay output 

          characteristics

          ·Number of contacts: 2NO (safety output)

          ·Contact material: AgSnO2

          ·Contact fuse protection: 10A is fast, 6A is slow.

          ·Switching capacity: 5A/230VAC;; 5A/24VDC

          Semiconductor output characteristics

          ·Number of contacts: 4SO (safety output)

          ·Contact fuse protection: 10A is fast, 6A is slow.

          ·Switching capacity: 2A/24VDC

          Time characteristic

          ·Suction buffer time: ≤100ms

          ·Release buffer time: ≤30ms

          ·Recovery time:

                   Emergency stop operation: ≤30ms

                   Power failure: ≤1000ms

          ·Recovery time:

                   Emergency stop operation: ≤30ms

                   Power failure: ≤100ms

          ·Short-term power interruption: 20ms

          Communication 

          characteristics

          ·Baud rate: 38.4kbps (fixed)

          ·Communication length: ≤1000m

          ·Networking capacity: ≤10 units


          Environmental characteristic parameters

          ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

          ·Vibration frequency: 10Hz~55Hz

          ·Vibration amplitude: 0.35mm

          ·Service temperature: -20℃~+60℃

          ·Storage temperature: -40℃~+85℃

          ·Relative humidity: 10%~90%

          ·Overvoltage grade: Ⅲ

          ·Pollution level: 2

          ·Altitude: ≤2000m

          ·Rated isolation voltage: 250VAC.

          ·Rated impulse voltage: 6000V(1.2/50us)

          ·Insulation strength: 1500VAC, 1min.

          ·Electrical clearance and creepage distance: in accordance with EN60947-1.

          1666333314320610.png


          Functional application parameters

          functional block diagram

          Typical application

          圖片3.png

          圖片4.png


          Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

          Input element: CH4 (emergency stop button); CH5 (emergency stop button); CH6 (reset button)

          Control logic: CH1&CH2CH4&CH5

          Reset mode: manual reset output delay: 0s.

          Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


          Wiring diagram

          Power Supply 

          1.png

          correspondence

          1655948458157829.png

          input

          3.png4.png5.png
          6.png7.png
          9.png10.png

          reset

          11.png12.png

          feedback

          13.png14.png

          output

          15.png16.png17.png


          Related Products
          Download
          PDF file download
          Video file download
          Previous

          Contact us

          400-881-6062

          Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

          E-Mail: info@lh-safety.com

          Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

          (Greenland East Coast International Plaza-Room A 313)

          Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

          Online service

          Online message

        2. Click to refresh
        3. 主站蜘蛛池模板: 小泽玛利亚三级片| 日本午夜精品理论片a级| 夜色资源站国产www在线视频| 狠狠亚洲色一日本高清色| 青海省| 无码午夜| 中国极品少妇videossexhd| 精品人妻少妇一区二区| 亚洲精品人妻中文字幕| 欧美一区二区三区国产精品| 国产无人区码一区二区| 99国产精品丝袜久久久久| 欧美不卡一区二区三区| 欧美老妇熟妇???亚洲日韩| 久久亚洲精品中文字幕馆| 性色综合网| 成人性生交片无码免费看| 亚洲亚洲人成无码网WWW| 国外少妇视频网站| 国产偷国产偷亚洲清高网站 | 亚洲熟女乱色综合亚洲| 亚洲国产片一区二区三区| 亚州无码成人| 亚洲国产成人无码网站大全| 亚洲欧美卡通另类丝袜美腿 | 天天做天天爱天天综合网2021| 亚洲乱色一区二区三区丝袜| AV色色色| 91福利精品老师国产自产在线 | 午夜一区二区三区视频| 人妻少妇偷人精品免费看| 无码AV一区二区三区无码| 国产农村妇女aaaaa视频| 3Pav图| 成人网中文字幕| 热久久这里超碰精品| 四虎8848精品成人免费网站| free性开放小少妇| 久久久久999| 国产人人操| 欧美日韩不卡中文字幕在线 |